Specifications
Case Size:
Width: 12.125 in. Length: 14.875 in. Height: 7.25 in. excluding cables
Wt. DT1530 & DT2030: about 15 lb., DT3050 & DT5050: about 23 lb.
Color: Safety Yellow
Environmental:
Light weight structural resin enclosure with water resistant front
panel. Lexan® panel overlay over aluminum sub-panel. Ergonomic handle.
Electrical:
- 120 VAC Input for the DT2030, 125/250 VAC Input for the DT5050
- Power required – 4 Watts nominal
- Circuit breaker protected:
- DT1530: 15 Amp and 30 Amp breakers
- DT2030: 20 Amp and 30 Amp breakers
- DT3050: 2 30 Amp breakers on the 125V side, 3 50 Amp breakers on the 250V side
- DT5050: 2 50 Amp breakers on the 125V side, 3 50 Amp breakers on the 250V side
- AC connector sets provided:
- DT1530: 125 VAC straight blade 15 Amp and 125 VAC 3 wire locking 30 Amp
- DT2030: 125 VAC 3 wire locking 20 Amp and 125 VAC 3 wire locking 30 Amp
- DT3050: 125 VAC 3 wire locking 30 Amp 125V and 125/250 VAC 4 wire
locking 50 Amp
- DT5050: 125 VAC 3 wire locking 50 Amp 125V and 125/250 VAC 4 wire
locking 50 Amp. The DT5050 may be used for testing 15A 125V,20A 125V, or 30A 125V by using
the appropriate adapters (not included).
- Silver/Silver-Chloride half cell probe used for in-water measurements
(optional, sold separately)
Standard Configuration:
Electrical Integrity
Test meter with specified AC connectors, one male and one female connector
for each amperage. The probe is not included with the
DockTester™
units but is available separately.
Have need of a custom configuration? Talk to us. We may be
able to do it for you.
One Year Warranty on all
DockTester™
Electrical Integrity Testers